X Fluke 98 Users Manual DECLARATION OF CONFORMITY for FLUKE 98 Automotive ScopeMeter® Series II Manufacturer Fluke Industrial B.V. Lelyweg 1 7602 EA Almelo The Netherlands Statement of Conformity Based on test results using appropriate standards, the product is in conformity with Electromagnetic Compatibility Directive 89/336/EEC Low Voltage.
Maximum Voltage Between any Terminal and Earth Ground 1000V de, 750V ac rms(sine) Fuse Protection 300 mA. 630 mA, 250V Fast Fuse 10A. 15A, 600V Fast Fuse Display Digital: 3,200 counts, updates 2.5/sec Analog: 32 segments, updates 25/sec Response Time of Digital Display V ac < 2 s V do < 1 s Ω < 1 s to 320 ΚΩ, < 2 s to 3.2 ΜΩ, < 10 s to 32 ΜΩ Operating Temperature 0°C to 50°C Storage Temperature -40°C to 60°C Temperature Coefficient 0.1 x (specified accuracy)/°C (<18°C or >28°C) Electromagnetic Compatibility - In an RF field of 3 V/m on all ranges and functions: Total Accuracy * Specified Accuracy +1.1% of range Relative Humidity Except 32 ΜΩ Range: Only: Battery Type Battery Life Continuity Beeper Shock, Vibration Size (HxWxL) Weight Safety 0% to 90% (0°C to 35°C) 0% to 70% (35°C to 50°C) 0% to 80% (0°C to 35°C) 0% to 70% (35°C to 50°C) 9V, NEDA 1604 or 6F22 or 006P 2000 hrs typical with alkaline 1600 hrs typical with carbon zinc 4096 Hz Per MIL-T-28800 for a Style B, Class 2 Instrument 2.8 cm x 7.5 cm x 16.6 cm (1.12 in x 2.95 in x 6.55 in) 340g (12oz) Designed to Protection Class II per IEC 348, ANSI/ISA-S82, UL1244, and CSA C22.2 No.231
Advertising
77/75/23/21 English Instruction Sheet
Page
1
®
77/75/23/21
Series III Multimeter
Instruction Sheet
W
Read First: Safety Information
•
Never use the meter if the meter or test leads look damaged.
•
Be sure the test leads and switch are in the correct position for
the desired measurement.
•
Never measure resistance in a circuit when power is applied.
•
Never touch the probes to a voltage source when the test
leads are plugged into the 10 A or 300 mA input jack.
•
Never apply more than the rated voltage between any input
jack and earth ground.
•
Be careful when working with voltages above 60 V dc or 30 V
ac rms. Such voltages pose a shock hazard.
•
Keep your fingers behind the finger guards on the test probes
when making measurements.
W
Warning
To avoid false readings, which could lead to
possible electric shock or personal injury, replace the battery as soon as the battery indicator (
M
)
appears.
Symbols
Fluke 23 Series Ii Multimeter User Manual 98025
W
Read First: Safety Information
Y
Dangerous Voltage May Be Present
T
Double Insulation
Overvoltage Installation Category per IEC 1010:
CAT II
CAT III
Typical locations include; main wall outlets,
local appliances, and portable equipment.
Typical locations include switches in the fixed
installation and equipment for industrial use permanently connected to the fixed installation.
PN 650512 August 1997 Rev.2, 7/98
Fluke 23 Multimeter Manual
1997, 1998 Fluke Corporation. All rights reserved. Printed in U.S.A.